-DAC変換開始トリガを使用の有無と使用する場合のトリガ・ソースを指示します。&br;
&br;
|CENTER:DAC_Trigger|CENTER:説明|h
|DAC_Trigger_None|Conversion is automatic once the DAC1_DHRxxxx register has beenloaded, and not by external trigger|
|DAC_Trigger_T6_TRGO|TIM6 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_T8_TRGO|TIM8 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_T7_TRGO|TIM7 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_T5_TRGO|TIM5 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_T2_TRGO|TIM2 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_T4_TRGO|TIM4 TRGO selected as external conversion trigger for DAC channel|
|DAC_Trigger_Ext_IT9|External interrupt 9 event selected as external conversion trigger for DAC channel|
|DAC_Trigger_Software|Conversion started by external software trigger for DAC channel|
|DAC_Trigger_None|トリガ無し|
|DAC_Trigger_T6_TRGO|TIM6 TRGO|
|DAC_Trigger_T8_TRGO|TIM8 TRGO|
|DAC_Trigger_T7_TRGO|TIM7 TRGO|
|DAC_Trigger_T5_TRGO|TIM5 TRGO|
|DAC_Trigger_T2_TRGO|TIM2 TRGO|
|DAC_Trigger_T4_TRGO|TIM4 TRGO|
|DAC_Trigger_Ext_IT9|外部割込み9|
|DAC_Trigger_Software|ソフトウェア|